Lightning Fast Speed
15mm*15mm, 15s/slide at 20x, 25s/slide at 40x Support Continuous Loading
Quiet and Stable Scanning
Magnetic suspension motor drive
99.85% slides scanned successfully
High Fidelity
High resolution 0.25 um/pixel (20X), 0.125um/pixel (40X) WSI scanning
High Precision
50nm positioning accuracy
Support 80x magnification
High Compatibility
Support bright-field and fluorescence
Support different image format
Professional Services
Customize products within a short time Provide in-time technical and after-sales services
| IMAGING & CAPACITY | ||||
| Name | KF-PRX-S 20-120 |
KF-PRX-M 150-480 |
KF-PRX-L 640 |
KF-PRX-XL 1200 |
| Brightfield | ||||
| Objective Type | 20x 0.8NA & 40x 0.95NA | |||
| Optical Magnification | 20x & 40x | |||
| Speed | 15 sec / slide , 20x 25 sec / slide, 40x |
|||
| Throughput | up to 90 slides / hour | up to 90 slides / hour | up to 100 slides / hour | up to 200 slides / hour |
| Scan Core Numbers | 1 | 1 | 1 | 2 |
| Resolution | 0.36 um/pixel at 20x, 0.18 um / pixel at 40x | |||
| Scan Method | Line Scanning | |||
| Output Format | .KFB, .SVS, .DCM, .TIFF | |||
| Fluorescence | ||||
| Objective Type | 20x 0.8NA & 40x 0.95NA | |||
| Optical Magnification | 40x & 80x | |||
| Speed | ≤6 min / slide, 10mm * 10mm, 3 filters ≤12 min / slide, 10mm * 10mm, 6 filters |
|||
| Scan Core Numbers | 1 | 1 | 1 | 1 |
| Resolution | 0.33 um/pixel at 20x, 0.17 um / pixel at 40x | |||
| Scan Method | Area Scanning | |||
| Output Format | .KFBF, .QPTIFF | |||
| Upgrade to Support Fluorescence | Yes | Yes | Yes | Yes |
| Fluorescence Channel Options | 3,4,6,8,10 | 3,4,6,8,10 | 3,4,6,8,10 | 3,4,6,8,10 |
| Common Paramters for Both Brightfield and Fluorescence | ||||
| Field of View (FOV) | 1mm | |||
| Z-Stack Scanning | ≤10 layers | |||
| Multi Layer Image Fusion | Support | |||
| Objective Lens | Evident X-Line UPLXAPO 20X, UPLXAPO 40X, Optional 4X / 10X / 50X / 60X | |||
| Objective Lens Sockets | 5 | |||
| Slide Capacity | 20~120 | 150~480 | 640 | 1200 |
| Slide Holder Type | Rack | Rack | Rack | Rack |
| Slide Holder Capacity | 20 | 20 or 30 | 20 | 20 |
| Slide Holder Number | Maximum 6 racks | Maximum 16 racks | 32 | 60 |
| Direct Placement of Racks With Handles Intact | Yes | Yes | No | No |
| Capacity for the Rack with Handle | Maximum 60 slides,
3 racks * 20 slides |
Maximum 240 slides, 8 racks * 30 slides |
– | – |
| Slide Pre-loading | No | No | Yes | Yes |
| Continuous Loading | Support | |||
| Slide Order Sorting Support | No | No | Yes | Yes |
| Label Identification | Support | |||
| DIMENSIONS & WEIGHT & POWER | ||||
| Scanner Dimensions (W x L x H) |
/ | 740*530*730 | 645*820*790 | 800*890*1535 |
| Power Supply Voltage Range | 100–240V AC, 50/60Hz | |||
| Power Socket Type | Type A、Type C、 Type D、Type E/F、Type G、Type I、Type J、Type L、Type M | |||
| IT & COMPUTER | ||||
| PC Model | Dell OptiPlex 7020MT Plus | |||
| PC Parameter | CPU: I5-14500
Memory: 32G*2 Harddisk: 1T SSD NVME |
|||
| Monitor | 24 Inch | |||
| Network Adopter | 1Gb RJ45 * 1 | |||
| Operation System | Windows 10 Professional 64bit | |||
| Slides | ||||
| General | The tissue/smear must be mounted with a coverslip, glass or tape. | |||
| Standard | 1-inch x 3-inch (2.54 cm x 7.62 cm) slides. Compatiable with ISO 8037/1. | |||
| Thickness | 0.9 mm ~ 1.1 mm, excluding coverslip | |||
| Special Requirement | The coverslip and attached label must remain fully within the microscope slide perimeter, secured with complete adhesive contact. All surfaces shall lie flat without edge separation. The slide exterior must maintain dryness with no fluid leakage from the specimen zone. | |||
| Maximum Tissue/Smear Thickness | Optimized for tissue thickness of 3-5 μm (including mounting media) | |||