Pathology Techniques Sharing – The Three Steps of Tissue Sectioning, Baking, and Drying

By Published On: 03/08/2024

Pathology Techniques Sharing – The Three Steps of Tissue Sectioning, Baking, and Drying

Highlights Both patients and pathologists aspire to achieve more accurate and standardized preparation of tissue samples, leading to more precise results and the prevention of errors. In this edition, we will share the specific steps of spreading, baking, and drying the tissue sections. We hope that this article can provide a more standardized operating procedure to assist pathologists in addressing difficulties.

Spreading (Sectioning):

El resto de este artículo se presenta en inglés para conservar el contenido técnico original.

1. Use Clean Water:

   – ✔ Regularly change the water in the floatation bath.

   – ❌ Although the water level in the floatation bath may be sufficient, failure to change it regularly could lead to contamination (such as fungi, molds) transferring onto the slides.

    Staining of microbial clusters on the plasma membrane surface of the gastrointestinal tract (H&E), although weak, can still be seen in the tissue, on slides, and outside the tissue. The source of these contaminants is most likely caused by spreading slides.

 

2. Ensure Clean Slides:

   – ✔ Before use, always check if the slides are clean to avoid contamination of squamous cells before spreading.

   – ❌ Neglecting to check slide cleanliness may result in dust, microorganisms, and other contaminants affecting the quality of the sections.

A. The kidney slide is contaminated with black contaminants already on the slide, and the contaminants can be seen elsewhere on the slide;

B, Lung-stained slides contain blurred portions of stained color, which could have been formed by tissue drying out. The binder (possibly gelatin) floats in a water bath, and the protein component of the binder becomes more concentrated as water vapor evaporates. Proper drainage prior to drying can resolve this problem.

3. Avoid Cross-Contamination:

   – ✔ To prevent cross-contamination between samples, remove residues from the previous specimen before spreading the next section.

   – ❌ Failure to clean the water surface between each wax block may lead to cross-contamination between different samples.

The heart muscle was contaminated with thyroid fragments. The cause may be due to contamination of different samples during the spreading process.

4. Prevent Squamous Cell Contamination:

   – ✔ Be cautious not to touch hair or skin during the spreading process to avoid squamous cell contamination.

   – ❌ Some sections produced by staff may contain a lot of squamous cells, and this can be avoided with better awareness.

The upper part of the kidney slide contained many foreign scales, which were probably deposited during the spreading process. They adhered firmly to the slide and were subsequently stained with eosin. 

5. Avoid Simultaneous Spreading of Sections from Different Wax Blocks:

   – ✔ Never simultaneously spread sections from different wax blocks.

   – ❌ Occasionally, sections from two or more wax blocks are spread simultaneously, which can lead to confusion and sample misidentification.

Sections from two different wax blocks are spread at the same time, which can lead to confusion or misidentification of samples.

6. Check Water Temperature:

   – ✔ Monitor the temperature of the floatation bath in real-time to ensure it is 4-5℃ below the melting point of the wax.

   – ❌ Sections left on the floatation bath for more than 15 seconds may cause the wax to melt, leading to tissue over-expansion and cell damage.

These skin slides have visible fissures and a large number of detached layers, typically caused by overexpansion. Improperly handled tissue is prone to this problem.

7. Prevent Wrinkles:

   – ✔ Place sections flat on the floatation bath.

   – ❌ If sections are not placed flat or if the floatation bath temperature is too low, wrinkles may occur during section retrieval.

In the picture, spreading the slides does not eliminate the wrinkles created by the slicing process. Better slicing techniques and slightly hotter water can help with this problem.

8. Avoid Overexpansion of Sections:

   – ✔ Immediately retrieve sections after spreading in the floatation bath.

   – ❌ Prolonged spreading in the floatation bath can lead to over-expansion and damage to tissues and cells, especially in delicate tissues like lymphoid tissues.

A. Sections of intestinal mucosa made using PAS staining: the lamina propria is overdistended (showing excessive separation of the intestinal glands), mainly due to prolonged spreading in an overheated bleachers.

B. Fissures in lymphoid tissue due to over-expansion in the bleachers. Lymphatic and hematopoietic tissues are particularly vulnerable.

9. Handle Floating Tissues Carefully:

   – ✔ Use forceps and brushes carefully when removing wrinkles, avoiding damage to tissues.

   – ❌ Excessive force when using forceps or brushes to remove wrinkles can impact tissue quality.

There is mechanical damage to the heart muscle (foramen), which is caused when trying to move slides that are stacked on top of each other (heart, H&E).

10. Carefully Select Sections:

    – ✔ Do not pick up the first or second section from each wax ribbon.

    – ❌ The first or second sections on each wax ribbon may appear better because they are thicker due to friction during the initial cutting of the cold wax block.

Each slide on the wax tape is numbered sequentially, and in the figure you can see that the first two slides are the widest (least extruded), but as the wax block temperature rise diminishes, the slides become narrower (more extruded). Although the microtome is set to 3 μm, the first two slides may have 4-5 μm due to thermal expansion.

 

11. Avoid Air Bubbles in Sections:

    – ✔ Carefully operate to prevent visible bubbles in the floatation bath. Eliminate any visible bubbles before placing sections for spreading.

    – ❌ Ignoring small bubbles in the floatation bath can lead to deformation in the sections, and these areas are likely to fall off during staining.

Liver H&E stained slide: there is a rounded, broken area, and this area of the slide appears to be bulging. The reason for this is that air bubbles were mixed into the section during the spreading process, which prevented the section from adhering flatly and firmly to the slide.

12. Prevent Section Curling:

    – ✔ Properly use charged or adhesive slides to prevent section curling.

    – ❌ Sections may detach during staining, especially after antigen retrieval or other heating methods, if charged or adhesive slides are not used.

Lung H&E-stained section: the section is cocked and covers the tissue next to it.

Baking/Drying Sections:

Before baking, ensure the water on the sections is drained. The baking temperature should not be too high, around 5-10℃ above the wax melting point. Baking time should be sufficient to dry the sections, which can be done using a slide baking machine or a constant-temperature oven.

Instrument Settings:

– Slide Baking Machine: 68°C for half an hour

– Constant Temperature Oven: Dry at 60°C for 2 hours

Considerations:

– Visible wrinkles on sections may result from inconsistent shrinkage between tissue and surrounding paraffin, creating waves or protrusions above the section surface.

– Adjust spreading water temperature and extend spreading time to address wrinkles.

– For unstable molecules, shorten the baking time or use frozen sections.

– Short baking time, low temperature, high temperature, or prolonged baking may cause tissue charring or shrinkage, resulting in wrinkles.

– Special tissues like the brain or spinal cord may require unique treatments, such as allowing thorough drying between section retrieval and baking, to prevent bubble formation.

Please note that these guidelines are based on the provided text, and it’s advisable to refer to specific equipment manuals and protocols for accurate settings and procedures.

This article is reprinted from Pathology Sea. Reproduction is to share viewpoints only, and the copyright belongs to the original author.

Learn more about KFBIO digital pathology solutions.

Written by : Kevin, Gui

Leave A Comment